EFGBP00037 | 2 Wheeler Battery
Experience the resilience of GREENFUEL batteries, uniquely crafted for two wheelers. Power up your ride with efficient and limitless performance.
Greenfuel, being an enabler in electric mobility proudly presents our newest offering in 2Wheelersegment in form of 2kWhSM Battery Pack with INT IOTbattery pack. This pack is designed for the harsh and abusive conditions applicable to 2W. With segment best safety features, energy density and state of the art thermal engineering, this battery pack offers the best performance and TCO. Equipped with advanced features like crash detection, redundant safety mechanisms, heater control, master/ slave adaptability and many more; the pack can be integrated in various architectures to ensure high efficiency. Needless to say, the battery pack is compliant to industry standards in terms of both safety and performance. Designed and developed with singular focus of being the ‘workhorse’, this battery pack will drive all the way.
- Long cycle life and NMC chemistrydelivering high energy density
- Flexibility in battery pack placement due to lower height: under the driver seat or under the cargo
- Capable to withstand side impact, drop and top loading
- High accuracy in voltage, current measurement
- Accuracy in SOC estimation > 98%
- Service friendly design, allows easy access to electronic and electro-mechanical components
- 100% Automotive qualified components
- Thermal management to ensure battery operation at controlled temperature
- 3+ years data and event storage locally at BMS level
- Environmental compliance as per ISO 16750
- UN38.3&AIS-004 certified
- Supports up to 2kW peak power
- 1000 cycle life under normal operating conditions
- Short circuit protection capability
- Rugged design: IP65
- Minimal self-discharge of < 2% per month, longer shelf life
- Wide operating temperature range makes it suitable for different terrains and environments.
Battery Capacity | 2Kwh |
Battery Type | Li-ion |
Chemistry | NMC |
Cell Package Type | Cylindrical |
Capacity | 40 Ah |
Operation DOD range | 83 + 2% |
Nominal voltage | 50.4 V |
Voltage Range | 43V – 58.38V |
Rated Charging Current (standard) | 0.5C |
Peak Charging Current | 1C |
Rated Discharge Current | 0.5C |
Peak Discharge Current | 2C for 10 Sec |
Sleep Current | < 5mA on HV side |
Communication Interface/Protocol | CAN2.0A |
Operating ambient temperature – Charging | 0 to 53`°C (cell temperature) |
Operating ambient temperature – Discharging | 0 to 58°C (cell temperature) |
Storage Temperature for 6 months | 0 to 35 (50% SOC) |
Cooling | Convection using thermal materials |
Lifecycle @ Ambient 25°C | ~1000 |
Deterioration in capacity over cycles at 25°C for 100% DOD and 0.5C | ~20% drop in initial capacity at the end of 1000 cycles. % drop in capacity at different part of the life shall be confirmed after simulation. |
Cycle definition | One complete charging and discharging considered to be a cycle for the above. |
Package Dimension (L x W x H) | (258*155*207mm) |
IP Protection | 65 |